{"id":1739,"date":"2015-03-14T14:49:02","date_gmt":"2015-03-14T14:49:02","guid":{"rendered":"http:\/\/vencotek.com\/?page_id=1739"},"modified":"2019-11-10T11:26:12","modified_gmt":"2019-11-10T11:26:12","slug":"terminal-ve-inline-uniteleri","status":"publish","type":"page","link":"https:\/\/vencotek.com\/en_US\/terminal-ve-inline-uniteleri\/","title":{"rendered":"Terminal and Inline Units"},"content":{"rendered":"<h2>Terminal and Inline Units<\/h2>\n<h4><span style=\"color: #9a1516;\">BDR<\/span> \u00a0 PLENUM FOR GRILLES<img loading=\"lazy\" class=\"alignright wp-image-1760\" src=\"http:\/\/vencotek.com\/wp-content\/uploads\/BDR-Grill.jpg\" alt=\"BDR-Grill\" width=\"247\" height=\"185\" \/><\/h4>\n<p>Ideal for spaces that need customization in grille sizes.<\/p>\n<p>The BDR plenum shall be made of galvanised steel.<\/p>\n<p>The plenum shall comprise an airflow measurement and adjustment unit.<\/p>\n<p>The grille shall be detachable to provide access to the measurement and adjustment module in the plenum.<\/p>\n<p>The plenum shall have mineral wool as sound insulation material.<\/p>\n<p>The plenum shall reduce duct pressure and air velocity in order to supply air through the whole face area of the grille and improve the air distribution quality.<\/p>\n<p>\u00a0<\/p>\n<div class=\"block_toggle_type_1\"><div class=\"button_outer \">\r\n                <div class=\"button_inner\"> OVERVIEW <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\u2022 Plenum for connecting supply\/exhaust grille to ductwork<br \/>\u2022 Ensures proper function of the supply air diffuser<br \/>\u2022 Wide range of grille dimensions and models<br \/>\u2022 Spring clips fastening of the grille<br \/>\u2022 Access for ductwork cleaning<\/p>\n<p><\/p>\r\n                <\/div><div class=\"button_outer \">\r\n                <div class=\"button_inner\"> PRODUCT MODELS &amp; ACCESSORIES <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\n<p>\u2022 Model with sound attenuation material<br \/>\u2022 Detachable airflow rate measurement and adjustment module<\/p>\n<p><\/p>\r\n                <\/div>\r\n                <script type=\"text\/javascript\">\r\n                    jQuery(\".block_toggle_type_1\").tabs(\".block_toggle_type_1 div.toggle_content\", {\r\n                        tabs : \".button_outer\",\r\n                        effect : \"slide\",\r\n                        toggle: true,\r\n                        initialIndex : 20\r\n                    });\r\n                <\/script>\r\n            <\/div>\n<p>\u00a0<\/p>\n<hr \/>\n<h4>\u00a0<\/h4>\n<h4><span style=\"color: #9a1516;\">HFD<\/span> \u00a0 MIXING CAV AND VAV BOX FOR DUAL DUCT SYSTEMS<img loading=\"lazy\" class=\"alignright size-full wp-image-1761\" src=\"http:\/\/vencotek.com\/wp-content\/uploads\/HFD-Grill.jpg\" alt=\"HFD-Grill\" width=\"260\" height=\"156\" \/><\/h4>\n<p>Circular mixing VAV and CAV box for dual duct systems with fast commissioning due to factory-set airflow limits (min.\/max. airflow rates).<\/p>\n<p>Pressure-independent operation.<\/p>\n<p>Tight shut-off operation at closed damper position. Ideal for renovation projects.<\/p>\n<p>The dual duct mixing unit shall be made of galvanised steel with airflow measurement probes of aluminium.<\/p>\n<p>Duct connections D = 100\u2026500 mm shall include airtight neoprene or EPDM rubber gaskets.<\/p>\n<p>Damper blades shall include rubber gaskets.<\/p>\n<p>The dual duct unit shall comprise airflow measurements, flow controllers and damper actuators.<\/p>\n<p>Design airflow range limits shall be calibrated at the factory.<\/p>\n<p>The casing shall be acoustically insulated with 25-mm-thick mineral wool to avoid airborne noise emission into the duct and radiation of noise through the damper casing.<\/p>\n<p>When specified, unit design shall have additional external insulation containing 40 mm of acoustic material and a galvanised steel cover applied over the standard casing.<\/p>\n<p>The dual duct unit shall be equipped with a sound attenuator in order to meet the sound level requirement for the room. As an option, the sound attenuator shall contain a central baffle.<\/p>\n<p>\u00a0<\/p>\n<div class=\"block_toggle_type_1\"><div class=\"button_outer \">\r\n                <div class=\"button_inner\"> OVERVIEW <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\u2022 Control damper for variable and constant airflow control applications in dual duct systems<br \/>\u2022 Pressure-independent operation<br \/>\u2022 Galvanized steel construction with insulation<br \/>\u2022 Tight shut-off operation at closed damper position<br \/>\u2022 Circular duct connection equipped with rubber gaskets<br \/>\u2022 Factory-set airflow range limits (min.\/max. airflow rates)<\/p>\n<p><\/p>\r\n                <\/div><div class=\"button_outer \">\r\n                <div class=\"button_inner\">PRODUCT MODELS &amp; ACCESSORIES <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\n<p>\u2022 Additional insulation option<br \/>\u2022 Sound attenuator<br \/>\u2022 Different outlet plenum options<\/p>\n<p><\/p>\r\n                <\/div>\r\n                <script type=\"text\/javascript\">\r\n                    jQuery(\".block_toggle_type_1\").tabs(\".block_toggle_type_1 div.toggle_content\", {\r\n                        tabs : \".button_outer\",\r\n                        effect : \"slide\",\r\n                        toggle: true,\r\n                        initialIndex : 20\r\n                    });\r\n                <\/script>\r\n            <\/div>\n<p>\u00a0<\/p>\n<hr \/>\n<h4><img loading=\"lazy\" class=\"alignright size-full wp-image-1763\" src=\"http:\/\/vencotek.com\/wp-content\/uploads\/cabin-unit.jpg\" alt=\"cabin-unit\" width=\"286\" height=\"190\" \/><\/h4>\n<h4>\u00a0<\/h4>\n<h4><span style=\"color: #9a1516;\">HFRM<\/span> \u00a0 MULTI-CONNECTION CABIN UNIT<\/h4>\n<p>The HFR\/M is an automatic or semi-automatic single duct cabin unit with 1-3 outlet connections for terminal units.<\/p>\n<p>The cabin unit includes a integrated reheater.<\/p>\n<p>Automatic operation is facilitated by continuous airflow measurement and damper regulation by intelligent control panel.<\/p>\n<p>Automatic HFR\/M adapts to variations in ductwork pressure and maintains individual conditions in each cabin and is thus pressure independent.<\/p>\n<p>Semi-automatic cabin unit does not include airflow measurement and is thus pressure dependent.<\/p>\n<p>HFR\/M is an excellent choice for suites, deluxe cabins and office areas where the total airflow needs to be distributed to several points, but controlled centrally with one control panel.<\/p>\n<p>\u00a0<\/p>\n<div class=\"block_toggle_type_1\"><div class=\"button_outer \">\r\n                <div class=\"button_inner\"> OVERVIEW <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\u2022 Pressure range from 200 Pa up to 1000 Pa<br \/>\u2022 Airflow range 175 m3\/h&#8230;1000 m3\/h<br \/>\u2022 230 VAC +-10%, max 10A, 50\/60 Hz<br \/>\u2022 Inbuilt airflow measurement (automatic models)<br \/>\u2022 Damper min. \/ max. position settings (semi-automatic)<br \/>\u2022 Triac controlled reheating coil(s), adjustable heating power (PWM) 0&#8230;100%<br \/>\u2022 Master\/slave functionality: several slave cabin units can be connected to one master cabin unit<br \/>\u2022 Internal fuses 8A or 10A and 63 mA<br \/>\u2022 Inputs for external switches such as balcony door and key card switches available as an option<br \/>\u2022 Network compatible with adapter for advanced energy efficiency and supervision system<br \/>\u2022 Energy efficiency functions to reduce unnecessary cooling \/ heating costs available as an option<br \/>\u2022 All parameters can be preset at the factory or set onsite during commissioning by PDA<br \/>\u2022 All cable connections with fast connectors<br \/>\u2022 Easily tailored for different types of installations<br \/>\u2022 90 \u00b0C manual reset safety switch with state detection indication to control panel<br \/>\u2022 Minimum flow alarm (automatic model) and inbox temperature measurement with overheat limit to cut-off reheater power<br \/>\u2022 HFR\/M cabin unit is supplied with control panel and interconnection cable<\/p>\n<p><\/p>\r\n                <\/div>\r\n                <script type=\"text\/javascript\">\r\n                    jQuery(\".block_toggle_type_1\").tabs(\".block_toggle_type_1 div.toggle_content\", {\r\n                        tabs : \".button_outer\",\r\n                        effect : \"slide\",\r\n                        toggle: true,\r\n                        initialIndex : 20\r\n                    });\r\n                <\/script>\r\n            <\/div>\n<p>\u00a0<\/p>\n<hr \/>\n<h4><img loading=\"lazy\" class=\"alignright size-full wp-image-1765\" src=\"http:\/\/vencotek.com\/wp-content\/uploads\/single-cabin-unit.jpg\" alt=\"single-cabin-unit\" width=\"283\" height=\"197\" \/><\/h4>\n<h4>\u00a0<\/h4>\n<h4><span style=\"color: #9a1516;\">HMC<\/span> \u00a0SINGLE DUCT CABIN UNIT<\/h4>\n<p>The HMC is a manually operated cabin unit for single duct applications.<\/p>\n<p>The unit can be installed directly through one ceiling blade (300 mm).<\/p>\n<p>Airflow is controlled via an adjusting knob installed through the diffuser.<\/p>\n<p>The control mechanism has mechanical limits for minimum and maximum airflows.<\/p>\n<p>Airflow limits can be easily set during commissioning.<\/p>\n<p>HMC is recommended to be used in conjunction with TCL diffuser that is specifically designed for HMC cabin unit.<\/p>\n<p>TBM\/K and TDM\/K diffusers are also available to be used with HMC.<\/p>\n<p>\u00a0<\/p>\n<div class=\"block_toggle_type_1\"><div class=\"button_outer \">\r\n                <div class=\"button_inner\"> OVERVIEW <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\n<p>\u2022 Pressure range from 0 Pa&#8230;200 Pa<br \/>\u2022 Airflow range 0 m3\/h&#8230;180 m3\/h<br \/>\u2022 Airflow adjustment with diffuser knob, painted with the diffuser color<br \/>\u2022 Mechanical max\/min airflow limits for easycommissioning<br \/>\u2022 Easily tailored for different types of installations<br \/>\u2022 MED approved for B-0\/B-15 installations<\/p>\n<p><\/p>\r\n                <\/div>\r\n                <script type=\"text\/javascript\">\r\n                    jQuery(\".block_toggle_type_1\").tabs(\".block_toggle_type_1 div.toggle_content\", {\r\n                        tabs : \".button_outer\",\r\n                        effect : \"slide\",\r\n                        toggle: true,\r\n                        initialIndex : 20\r\n                    });\r\n                <\/script>\r\n            <\/div>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<hr \/>\n<h4>\u00a0<\/h4>\n<h4><span style=\"color: #9a1516;\">HME<\/span> \u00a0 SINGLE DUCT CABIN UNIT<img loading=\"lazy\" class=\"alignright size-full wp-image-1766\" src=\"http:\/\/vencotek.com\/wp-content\/uploads\/single-duct-cabin.jpg\" alt=\"single-duct-cabin\" width=\"287\" height=\"192\" \/><\/h4>\n<p>The HME can be used for air distribution and sound attenuation in various applications such as suites and pantries.<\/p>\n<p>The unit operates as a plenum box with a balancing and measurement module inside but also fulfils fire safety requirements as standard cabin unit.<\/p>\n<p>The supply volume flow rate is determined during commissioning by using the measurement and adjustment device. The flow measurement tubes and control spindle can be accessed through the unit outlet.<\/p>\n<p>Using the pressure difference readings between the measurement taps and the k coefficient, the corresponding volume flow rate can be calculated.<\/p>\n<p>Rotating the control spindle adjusts the volume flow rate until the desired setting is achieved.<\/p>\n<p>\u00a0<\/p>\n<div class=\"block_toggle_type_1\"><div class=\"button_outer \">\r\n                <div class=\"button_inner\"> OVERVIEW <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\u2022 Recommended pressure range from 0 Pa to 200 Pa<br \/>\u2022 Airflow range 0 m3\/h&#8230;500 m3\/h<br \/>\u2022 Excellent choice to be used together with HFR\/M<br \/>\u2022 Airflow adjustment with control spindle (MSM module)<br \/>\u2022 Airflow measurement tubes<br \/>\u2022 Can be used also as exhaust plenum<br \/>\u2022 MED approved for B-0\/B-15 installations<\/p>\n<p><\/p>\r\n                <\/div><div class=\"button_outer \">\r\n                <div class=\"button_inner\">ADDITIONAL FEATURES WITH REHEAT MODELS <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\n<p>\u2022 230 VAC +- 10%, max 10A, 50\/60 Hz<br \/>\u2022 Triac controlled reheating coil(s), adjustable heating power (PWM) 0&#8230;100%<br \/>\u2022 Master\/slave functionality: several slave cabin units can be connected to one master cabin unit<br \/>\u2022 Internal fuses 8A or 10A and 63 mA<br \/>\u2022 Network compatible with adapter<br \/>\u2022 All parameters can be preset at the factory or set onsite during commissioning by PDA<br \/>\u2022 All cable connections with fast connectors<br \/>\u2022 Easily tailored for different types of installations<br \/>\u2022 90 \u00b0C safety switch with state detection and manual reset<br \/>\u2022 HME cabin unit is supplied with control panel and interconnection cable<\/p>\n<p><\/p>\r\n                <\/div>\r\n                <script type=\"text\/javascript\">\r\n                    jQuery(\".block_toggle_type_1\").tabs(\".block_toggle_type_1 div.toggle_content\", {\r\n                        tabs : \".button_outer\",\r\n                        effect : \"slide\",\r\n                        toggle: true,\r\n                        initialIndex : 20\r\n                    });\r\n                <\/script>\r\n            <\/div>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n<hr \/>\n<h4>\u00a0<\/h4>\n<h4><span style=\"color: #9a1516;\">HMF<\/span> \u00a0SINGLE DUCT CABIN UNIT<img loading=\"lazy\" class=\"alignright wp-image-1767\" src=\"http:\/\/vencotek.com\/wp-content\/uploads\/ducts_03.jpg\" alt=\"ducts_03\" width=\"249\" height=\"178\" \/><\/h4>\n<p>The HMF is an automatic or semi-automatic single duct cabin unit with intergrated reheater.<\/p>\n<p>Automatic operation is facilitated by continuous airflow measurement and damper regulation by intelligent control panel.<\/p>\n<p>Automatic HMF adapts to variations in ductwork pressure and maintains individual conditions in each cabin and is thus pressure independent.<\/p>\n<p>Semi-automatic cabin unit does not include airflow measurement and is thus pressure dependent.<\/p>\n<p>\u00a0<\/p>\n<div class=\"block_toggle_type_1\"><div class=\"button_outer \">\r\n                <div class=\"button_inner\"> OVERVIEW <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\u2022 Pressure range from 200 Pa up to 1000 Pa<br \/>\u2022 Airflow range 120 m3\/h&#8230;500 m3\/h<br \/>\u2022 230 VAC+-10%, max 10A, 50\/60 Hz<br \/>\u2022 Inbuilt airflow measurement (automatic models)<br \/>\u2022 Damper min. \/ max. position settings (semi-automatic)<br \/>\u2022 Triac controlled reheating coil(s), adjustable heating power (PWM) 0&#8230;100%<br \/>\u2022 Master\/slave functionality: several slave cabin units can be connected to one master cabin unit<br \/>\u2022 Internal fuses 8A or 10A and 63 mA<br \/>\u2022 Inputs for external switches such as balcony door and key card switches available as an option<br \/>\u2022 Network compatible with adapter for advanced energy efficiency and supervision system<br \/>\u2022 Energy efficiency functions to reduce unnecessary cooling \/ heating costs available as an option<br \/>\u2022 All parameters can be preset at the factory or set onsite during commissioning by PDA<br \/>\u2022 All cable connections with fast connectors<br \/>\u2022 Easily tailored for different types of installations<br \/>\u2022 90 \u00b0C safety switch with state detection and manual reset<br \/>\u2022 Minimum flow alarm (automatic model) and inbox temperature measurement with overheat limit to cut-off reheater power<br \/>\u2022 HMF cabin unit is supplied with control panel and interconnection cable<br \/>\u2022 MED approved for B-0\/B-15 installations<\/p>\n<p><\/p>\r\n                <\/div>\r\n                <script type=\"text\/javascript\">\r\n                    jQuery(\".block_toggle_type_1\").tabs(\".block_toggle_type_1 div.toggle_content\", {\r\n                        tabs : \".button_outer\",\r\n                        effect : \"slide\",\r\n                        toggle: true,\r\n                        initialIndex : 20\r\n                    });\r\n                <\/script>\r\n            <\/div>\n<p>\u00a0<\/p>\n<hr \/>\n<h4>\u00a0<\/h4>\n<h4><span style=\"color: #9a1516;\">HMM<\/span> \u00a0 SINGLE DUCT CABIN UNIT<img loading=\"lazy\" class=\"alignright size-full wp-image-1768\" src=\"http:\/\/vencotek.com\/wp-content\/uploads\/ducts_06.jpg\" alt=\"ducts_06\" width=\"260\" height=\"199\" \/><\/h4>\n<p>The HMM is a manually operated cabin unit for single duct applications.<\/p>\n<p>Airflow is controlled via an adjusting knob installed on the diffuser.<\/p>\n<p>The control mechanism has mechanical limits for minimum and maximum airflows.<\/p>\n<p>These limits can be easily set during commissioning.<\/p>\n<p>HMM is recommended to be used in conjunction with TBM\/K or TDM\/K diffusers, as the mechanism has to be fixed to the diffuser structure.<\/p>\n<p>The airflow is adjusted with diffuser knob.<\/p>\n<p>The HMM cabin unit can be supplied with reheater &#8211; controlled by control panel.<\/p>\n<p>\u00a0<\/p>\n<div class=\"block_toggle_type_1\"><div class=\"button_outer \">\r\n                <div class=\"button_inner\"> OVERVIEW <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\u2022 Pressure range from 50 Pa up to 1000 Pa<br \/>\u2022 Airflow range 0 m3\/h&#8230;500 m3\/h<br \/>\u2022 Airflow adjustment with diffuser knob<br \/>\u2022 Mechanical max.\/min. airflow limits for easy commissioning<br \/>\u2022 Airflow measurement pipes<br \/>\u2022 MED approved for B-0 and B-15 installations<\/p>\n<p><\/p>\r\n                <\/div><div class=\"button_outer \">\r\n                <div class=\"button_inner\"> ADDITIONAL FEATURES WITH REHEAT MODELS <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\n<p>\u2022 230 VAC+-10%, max 10A, 50\/60 Hz<br \/>\u2022 Triac controlled reheating coil(s), adjustable heating power (PWM) 0&#8230;100%<br \/>\u2022 Master\/slave functionality: several slave cabin unitscan be connected to one master cabin unit<br \/>\u2022 Internal fuses 8A or 10A and 63 mA<br \/>\u2022 Network compatible with adapter<br \/>\u2022 All parameters can be preset at the factory or setonsite during commissioning by PDA<br \/>\u2022 All cable connections with fast connectors<br \/>\u2022 Easily tailored for different types of installations<br \/>\u2022 90\u00b0C safety switch with state detection and manual reset<br \/>\u2022 HMM cabin unit is supplied with control panel and interconnection cable<\/p>\n<p><\/p>\r\n                <\/div>\r\n                <script type=\"text\/javascript\">\r\n                    jQuery(\".block_toggle_type_1\").tabs(\".block_toggle_type_1 div.toggle_content\", {\r\n                        tabs : \".button_outer\",\r\n                        effect : \"slide\",\r\n                        toggle: true,\r\n                        initialIndex : 20\r\n                    });\r\n                <\/script>\r\n            <\/div>\n<p>\u00a0<\/p>\n<hr \/>\n<h4>\u00a0<\/h4>\n<h4><span style=\"color: #9a1516;\">HMR<\/span> \u00a0DUAL DUCT CABIN UNIT<img loading=\"lazy\" class=\"alignright wp-image-1769\" src=\"http:\/\/vencotek.com\/wp-content\/uploads\/dual-duct_03.jpg\" alt=\"dual-duct_03\" width=\"222\" height=\"155\" \/><\/h4>\n<p>The HMR is an automatic dual duct cabin unit.<\/p>\n<p>The airflow is continuously measured from the warm air spigot, as well as for total air volume.<\/p>\n<p>Automatic HMR adapts to variations in ductwork pressure and maintains individual conditions in each cabin and is thus pressure independent.<\/p>\n<p>\u00a0<\/p>\n<div class=\"block_toggle_type_1\"><div class=\"button_outer \">\r\n                <div class=\"button_inner\"> OVERVIEW <\/div>\r\n                <div class=\"icon\">\r\n                <span><\/span>\r\n                <\/div><\/div>\r\n                \r\n                <div class=\"toggle_content\">\r\n                    <p>\u2022 Pressure range from 200 Pa up to 1000 Pa<br \/>\u2022 Airflow range 120 m3\/h&#8230;400 m3\/h<br \/>\u2022 230 VAC+-10%, max 1A, 50\/60 Hz<br \/>\u2022 Inbuilt airflow measurements<br \/>\u2022 Master\/slave functionality: several slave cabin units can be connected to one master cabin unit<br \/>\u2022 Internal fuse 63 mA<br \/>\u2022 Inputs for external switches such as balcony door and key card switches available as an option<br \/>\u2022 Inputs to connect balcony door or other external devices available as an option<br \/>\u2022 Energy efficiency functions to reduce unnecessary cooling \/ heating costs available as an option<br \/>\u2022 All parameters can be preset at the factory or set onsite during commissioning by PDA<br \/>\u2022 Different regulation principles available according to supply air temperatures (see regulation diagrams)<br \/>\u2022 HMR cabin unit is supplied with control panel and interconnection cable<br \/>\u2022 MED approved for B-0\/B-15 installations<\/p>\n<p><\/p>\r\n                <\/div>\r\n                <script type=\"text\/javascript\">\r\n                    jQuery(\".block_toggle_type_1\").tabs(\".block_toggle_type_1 div.toggle_content\", {\r\n                        tabs : \".button_outer\",\r\n                        effect : \"slide\",\r\n                        toggle: true,\r\n                        initialIndex : 20\r\n                    });\r\n                <\/script>\r\n            <\/div>\n<p>\u00a0<\/p>\n<p>\u00a0<\/p>\n","protected":false},"excerpt":{"rendered":"<h2>Terminal and Inline Units<\/h2>\n<h4><span style=\"color: #9a1516;\">BDR<\/span> \u00a0 PLENUM FOR GRILLES<img loading=\"lazy\" class=\"alignright wp-image-1760\" src=\"http:\/\/vencotek.com\/wp-content\/uploads\/BDR-Grill.jpg\" alt=\"BDR-Grill\" width=\"247\" height=\"185\" \/><\/h4>\n<p>Ide&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"open","template":"template-page-fullwidth.php","meta":[],"_links":{"self":[{"href":"https:\/\/vencotek.com\/wp-json\/wp\/v2\/pages\/1739"}],"collection":[{"href":"https:\/\/vencotek.com\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/vencotek.com\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/vencotek.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/vencotek.com\/wp-json\/wp\/v2\/comments?post=1739"}],"version-history":[{"count":31,"href":"https:\/\/vencotek.com\/wp-json\/wp\/v2\/pages\/1739\/revisions"}],"predecessor-version":[{"id":1741,"href":"https:\/\/vencotek.com\/wp-json\/wp\/v2\/pages\/1739\/revisions\/1741"}],"wp:attachment":[{"href":"https:\/\/vencotek.com\/wp-json\/wp\/v2\/media?parent=1739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}